Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 39
Page 239
Heat - actuated devices shall be installed , one on each side of the wall at the top
of the opening and one on each side of the wall at ceiling height where the
ceiling is more than three feet ( 3 ' ) above the opening . Interconnected doors
shall ...
Heat - actuated devices shall be installed , one on each side of the wall at the top
of the opening and one on each side of the wall at ceiling height where the
ceiling is more than three feet ( 3 ' ) above the opening . Interconnected doors
shall ...
Page 271
It shall be unlawful for any person , firm or cor - General poration to install or alter
or cause to be installed or altered , any system of refrigeration , unless such
system is an approved type and is installed in accordance with the provisions of
the ...
It shall be unlawful for any person , firm or cor - General poration to install or alter
or cause to be installed or altered , any system of refrigeration , unless such
system is an approved type and is installed in accordance with the provisions of
the ...
Page 273
for each blower - type warm air furnace installed in such room plus two hundred
square inches ( 200 sq . in . ) for each gravity - type warm air furnace installed in
such room , and in no case shall have a net area of less than one square inch ( 1
...
for each blower - type warm air furnace installed in such room plus two hundred
square inches ( 200 sq . in . ) for each gravity - type warm air furnace installed in
such room , and in no case shall have a net area of less than one square inch ( 1
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood