Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 29
Page 108
... lateral strength of the wood screw as set forth in Table No. 25 - D . Screws shall have an embedment into the ... Lateral Strength . A wire nail inserted perpendicular to the grain of the wood when used to fasten wooden members together ...
... lateral strength of the wood screw as set forth in Table No. 25 - D . Screws shall have an embedment into the ... Lateral Strength . A wire nail inserted perpendicular to the grain of the wood when used to fasten wooden members together ...
Page 150
... lateral dimension . When the unsupported length exceeds this value , the design shall be modified as shown in ... lateral deflection . 4. In columns restrained laterally by struts or beams , with brackets used at the junction , it shall ...
... lateral dimension . When the unsupported length exceeds this value , the design shall be modified as shown in ... lateral deflection . 4. In columns restrained laterally by struts or beams , with brackets used at the junction , it shall ...
Page 153
... lateral dimen- sion . In such case the permissible load , the gross area consid- ered , and the required percentage of reinforcement must be taken as those of the circular column . - ( d ) Tied Columns . 1. Permissible Load The maximum ...
... lateral dimen- sion . In such case the permissible load , the gross area consid- ered , and the required percentage of reinforcement must be taken as those of the circular column . - ( d ) Tied Columns . 1. Permissible Load The maximum ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood