Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 26
Page 235
... lath 2 * 2 * Hollow Stud Partition with Gypsum or Portland Cement Plaster or Pneumatically Placed Plaster on Each Side Incombustible studding with metal or wire lath . 1 - in . plaster on each side Wood studs with metal or wire lath ...
... lath 2 * 2 * Hollow Stud Partition with Gypsum or Portland Cement Plaster or Pneumatically Placed Plaster on Each Side Incombustible studding with metal or wire lath . 1 - in . plaster on each side Wood studs with metal or wire lath ...
Page 246
... Lath . Wood lath shall conform to the require- ments of Section 13 ( b ) of A.S.A. " Standard Specifications for Gypsum Plastering Including Requirements for Lathing and Furring , " ( A42 , 1-1938 ) . ( g ) Fiber Insulation . Fiber ...
... Lath . Wood lath shall conform to the require- ments of Section 13 ( b ) of A.S.A. " Standard Specifications for Gypsum Plastering Including Requirements for Lathing and Furring , " ( A42 , 1-1938 ) . ( g ) Fiber Insulation . Fiber ...
Page 248
... LATH MAXIMUM SPACING OF SUPPORTS TYPES OF LATH WEIGHT ( lbs . per sq . yd . FOR WALLS FOR CEILINGS Wire Lath 2.48 16 " 12 " Flat Expanded 2.5 16 " 0 Flat Expanded 3.4 16 " 16 " Flat Rib 2.75 16 " 16 " Flat Rib 3.4 24 " 24 " 3/8 " Rib ...
... LATH MAXIMUM SPACING OF SUPPORTS TYPES OF LATH WEIGHT ( lbs . per sq . yd . FOR WALLS FOR CEILINGS Wire Lath 2.48 16 " 12 " Flat Expanded 2.5 16 " 0 Flat Expanded 3.4 16 " 16 " Flat Rib 2.75 16 " 16 " Flat Rib 3.4 24 " 24 " 3/8 " Rib ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood