Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 84
Page 57
... least 50 per cent open on at least two sides . The width of such courts or yards shall be not less than three feet ( 3 ′ ) when such courts or yards are not more than two stories high measured down from the top of the building and shall ...
... least 50 per cent open on at least two sides . The width of such courts or yards shall be not less than three feet ( 3 ′ ) when such courts or yards are not more than two stories high measured down from the top of the building and shall ...
Page 87
... least 48 hours after being laid . No masonry shall be built upon frozen material . ( d ) Dimensions . Dimensions given are nominal ; actual dimensions of unit masonry may not be decreased by more than one - half inch ( 1⁄2 " ) . Sec ...
... least 48 hours after being laid . No masonry shall be built upon frozen material . ( d ) Dimensions . Dimensions given are nominal ; actual dimensions of unit masonry may not be decreased by more than one - half inch ( 1⁄2 " ) . Sec ...
Page 88
... least equal to that required by A.C.I. " Specifications for Cast Stone , " ( 704-44 ) . ( e ) Stone . Natural stone shall be sound and free from loose or friable inclusions , with sufficient strength and dura- bility for the proposed ...
... least equal to that required by A.C.I. " Specifications for Cast Stone , " ( 704-44 ) . ( e ) Stone . Natural stone shall be sound and free from loose or friable inclusions , with sufficient strength and dura- bility for the proposed ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood