Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 43
Page 35
... less than four - hour fire - resistive construction . 2. A " Special Occupancy Separation " shall be of not less ... one story shall not exceed 25 per cent of the length of the wall in that story and no single opening shall have an area ...
... less than four - hour fire - resistive construction . 2. A " Special Occupancy Separation " shall be of not less ... one story shall not exceed 25 per cent of the length of the wall in that story and no single opening shall have an area ...
Page 72
Pacific Coast Building Officials Conference, International Conference of Building Officials. Floor of two - hour fire - resistive protection for columns and one ... less than one inch ( 1 ′′ ) . 2. The masonry over window openings may be ...
Pacific Coast Building Officials Conference, International Conference of Building Officials. Floor of two - hour fire - resistive protection for columns and one ... less than one inch ( 1 ′′ ) . 2. The masonry over window openings may be ...
Page 236
... hour , three - hour and two - hour fire - resistive floors as specified in ... less than four inches ( 4 " ) in thickness or shall consist of hollow ... one and one - half inches ( 11⁄2 " ) in thickness , or shall consist of steel joists ...
... hour , three - hour and two - hour fire - resistive floors as specified in ... less than four inches ( 4 " ) in thickness or shall consist of hollow ... one and one - half inches ( 11⁄2 " ) in thickness , or shall consist of steel joists ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood