Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 17
Page 100
... lumber members required by this Code refer to nominal sizes . American Lumber Standard dressed sizes shall be accepted as the minimum net sizes conforming to nominal sizes . Computations to determine the required sizes of members shall ...
... lumber members required by this Code refer to nominal sizes . American Lumber Standard dressed sizes shall be accepted as the minimum net sizes conforming to nominal sizes . Computations to determine the required sizes of members shall ...
Page 118
... Lumber surfaces shall not be sanded before gluing . Sec . 2529. ( a ) General . The allowable stresses in glued laminated structural lumber shall be as specified in this section . Whenever glued laminated lumber is an integral part of ...
... Lumber surfaces shall not be sanded before gluing . Sec . 2529. ( a ) General . The allowable stresses in glued laminated structural lumber shall be as specified in this section . Whenever glued laminated lumber is an integral part of ...
Page 259
... Lumber Standards for Softwood Lumber 2503 ( a ) LLL - F - 321b SS - C - 181b 4702 ( g ) Federal Specifications for Masonry Cement 2402 ( i ) , 2403 ( a ) R896 R1025 R1220 April 17 , 1942 2528 2524 2530 2503 ( e ) United States Federal ...
... Lumber Standards for Softwood Lumber 2503 ( a ) LLL - F - 321b SS - C - 181b 4702 ( g ) Federal Specifications for Masonry Cement 2402 ( i ) , 2403 ( a ) R896 R1025 R1220 April 17 , 1942 2528 2524 2530 2503 ( e ) United States Federal ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood