... masonry General materials shall conform to the minimum requirements specified in this Chapter . Masonry units may be re - used when clean , sound , and conforming to the other requirements of this Chap- ter . Masonry construction shall ...
... masonry General materials shall conform to the minimum requirements specified in this Chapter . Masonry units may be re - used when clean , sound , and conforming to the other requirements of this Chap- ter . Masonry construction shall ...
Page 96
... Masonry Sec . 2408. ( a ) General . Hollow unit masonry is that type of construction made with structural clay tile or hollow con- crete masonry units in which the units are all laid and set in mortar . Types A , B , or C mortar shall ...
... Masonry Sec . 2408. ( a ) General . Hollow unit masonry is that type of construction made with structural clay tile or hollow con- crete masonry units in which the units are all laid and set in mortar . Types A , B , or C mortar shall ...
Page 97
... masonry units are laid with cells vertical , rectangular ties shall be used . The ends of ties shall be bent to 90 degree angles to provide hooks not less than two inches ( 2 ′′ ) long . Additional bonding ... Masonry 2411 Gypsum Masonry.
... masonry units are laid with cells vertical , rectangular ties shall be used . The ends of ties shall be bent to 90 degree angles to provide hooks not less than two inches ( 2 ′′ ) long . Additional bonding ... Masonry 2411 Gypsum Masonry.
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood