Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 85
Page 88
... Materials . Cementitious materials used in mortars shall be of a quality at least equal to the quality of materials required by the following applicable specifications : A.S.T.M. " Standard Specifications for Quicklime for Structural ...
... Materials . Cementitious materials used in mortars shall be of a quality at least equal to the quality of materials required by the following applicable specifications : A.S.T.M. " Standard Specifications for Quicklime for Structural ...
Page 125
... materials for ready mixed concrete shall conform to the A.S.T.M. " Standard Specifications for Ready Mixed Concrete , " ( C94-44 ) . Admixtures of lime or finely pulverized inert materials may be added but not in excess of six per cent ...
... materials for ready mixed concrete shall conform to the A.S.T.M. " Standard Specifications for Ready Mixed Concrete , " ( C94-44 ) . Admixtures of lime or finely pulverized inert materials may be added but not in excess of six per cent ...
Page 213
... Materials . No wood or other combustible materials shall be placed within six inches ( 6 " ) of the fireplace opening . No such combustible material within twelve inches ( 12 " ) of the fireplace opening shall project more than one ...
... Materials . No wood or other combustible materials shall be placed within six inches ( 6 " ) of the fireplace opening . No such combustible material within twelve inches ( 12 " ) of the fireplace opening shall project more than one ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood