Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 22
Page 73
... measured at right angles to the plane of the wall in which such openings occur . 2. The provisions of this section shall not apply to openings in an outer court twenty feet ( 20 ′ ) or more in width parallel to and facing upon a street ...
... measured at right angles to the plane of the wall in which such openings occur . 2. The provisions of this section shall not apply to openings in an outer court twenty feet ( 20 ′ ) or more in width parallel to and facing upon a street ...
Page 125
... Measurement of materials for ready mixed concrete shall conform to the A.S.T.M. " Standard Specifications for Ready ... measuring concrete materials Control of shall be such that the proportions of all materials can be Proportions ...
... Measurement of materials for ready mixed concrete shall conform to the A.S.T.M. " Standard Specifications for Ready ... measuring concrete materials Control of shall be such that the proportions of all materials can be Proportions ...
Page 233
... measured as specified for solid masonry walls in this paragraph . Where hollow units are laid with cells vertical ( end construction ) and the hollow spaces are not thus filled , the re- quired effective thickness of walls shall be measured ...
... measured as specified for solid masonry walls in this paragraph . Where hollow units are laid with cells vertical ( end construction ) and the hollow spaces are not thus filled , the re- quired effective thickness of walls shall be measured ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood