Page 90
... MINIMUM THICKNESS OF MASONRY WALLS Maximum Ratio Nominal Unsupported Minimum Type of Masonry Height or Length Thickness to Thickness ( Inches ) Plain Solid Masonry 20 Grouted Brick Masonry 22 Reinforced Brick Masonry 25 Hollow Unit ...
... MINIMUM THICKNESS OF MASONRY WALLS Maximum Ratio Nominal Unsupported Minimum Type of Masonry Height or Length Thickness to Thickness ( Inches ) Plain Solid Masonry 20 Grouted Brick Masonry 22 Reinforced Brick Masonry 25 Hollow Unit ...
Page 127
... minimum thickness of the bar . Bends for other bars , except hooks , shall be made around a pin having a diameter not less than six times the minimum thickness of the bar , except that for bars larger than one inch , the pin shall be ...
... minimum thickness of the bar . Bends for other bars , except hooks , shall be made around a pin having a diameter not less than six times the minimum thickness of the bar , except that for bars larger than one inch , the pin shall be ...
Page 146
... Minimum = 1.25 12 ( Maximum = 1.50 t2 ( Minimum = 1.25 t2 ( Maximum = 1.50 t Minimum side or diameter of Dropped Panel bi Feet 0.3511 0.3541 Numerical sum of positive and negative moments in direction of either side of interior rec ...
... Minimum = 1.25 12 ( Maximum = 1.50 t2 ( Minimum = 1.25 t2 ( Maximum = 1.50 t Minimum side or diameter of Dropped Panel bi Feet 0.3511 0.3541 Numerical sum of positive and negative moments in direction of either side of interior rec ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood