Page 27
... Occupancy . No new building or struc- ture in Groups A to H , inclusive , shall be used or occupied , and no change in the existing occupancy classification of a building or structure or portion thereof shall be made until the Building ...
... Occupancy . No new building or struc- ture in Groups A to H , inclusive , shall be used or occupied , and no change in the existing occupancy classification of a building or structure or portion thereof shall be made until the Building ...
Page 34
... Occupancy PART III REQUIREMENTS BASED ON OCCUPANCY CHAPTER 5 - CLASSIFICATION OF ALL BUILD- INGS BY USE OR OCCUPANCY AND GENERAL REQUIREMENTS FOR ALL OCCUPANCIES Sec . 501. Every building , whether existing or hereafter erected , shall ...
... Occupancy PART III REQUIREMENTS BASED ON OCCUPANCY CHAPTER 5 - CLASSIFICATION OF ALL BUILD- INGS BY USE OR OCCUPANCY AND GENERAL REQUIREMENTS FOR ALL OCCUPANCIES Sec . 501. Every building , whether existing or hereafter erected , shall ...
Page 35
... Occupancy Separation . Occupancy separations Mixed shall be classed as " Absolute , " " Special " and " Ordinary . " Occupancy 1. An " Absolute Occupancy Separation " shall have no open- ( Cont'd . ) ings therein and shall be of not ...
... Occupancy Separation . Occupancy separations Mixed shall be classed as " Absolute , " " Special " and " Ordinary . " Occupancy 1. An " Absolute Occupancy Separation " shall have no open- ( Cont'd . ) ings therein and shall be of not ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood