Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 37
Page 24
... permit for each such building or structure from the Building Official . ( b ) Applicaton . To obtain a permit the ... Permits and Inspections SEC 301 Application for Permits Building Permits 302.
... permit for each such building or structure from the Building Official . ( b ) Applicaton . To obtain a permit the ... Permits and Inspections SEC 301 Application for Permits Building Permits 302.
Page 25
... permit or approval of plans and specifications shall not be construed to be a permit for , or an approval of , any violation of any of the provisions of this Code . No permit presuming to give authority to violate or cancel the ...
... permit or approval of plans and specifications shall not be construed to be a permit for , or an approval of , any violation of any of the provisions of this Code . No permit presuming to give authority to violate or cancel the ...
Page 26
... permit is required by this Code is started or proceeded with prior to obtaining said permit , the fees above specified shall be doubled , but the payment of such double fee shall not relieve any persons from fully complying with the ...
... permit is required by this Code is started or proceeded with prior to obtaining said permit , the fees above specified shall be doubled , but the payment of such double fee shall not relieve any persons from fully complying with the ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood