Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 65
Page 25
... permit or approval of plans and specifications shall not be construed to be a permit for , or an approval of , any violation of any of the provisions of this Code . No permit presuming to give authority to violate or cancel the ...
... permit or approval of plans and specifications shall not be construed to be a permit for , or an approval of , any violation of any of the provisions of this Code . No permit presuming to give authority to violate or cancel the ...
Page 38
... Permitted 15000 21250 6250 12500 18750 30000 15000 Unlimited Not Permitted Not Permitted Not Permitted 6000 8500 2500 5000 7500 12000 ] 6000 Unlimited Note : For Group J Occupancy see Chapter 15 . 9000 12750 3750 7500 11250 18000 9000 ...
... Permitted 15000 21250 6250 12500 18750 30000 15000 Unlimited Not Permitted Not Permitted Not Permitted 6000 8500 2500 5000 7500 12000 ] 6000 Unlimited Note : For Group J Occupancy see Chapter 15 . 9000 12750 3750 7500 11250 18000 9000 ...
Page 105
... permitted for a square col- umn of the same cross - sectional area . Sec . 2506. Members subject to both axial and bending stresses Combined shall be proportioned in accordance with the following formula : Stresses P / A M / S + equals ...
... permitted for a square col- umn of the same cross - sectional area . Sec . 2506. Members subject to both axial and bending stresses Combined shall be proportioned in accordance with the following formula : Stresses P / A M / S + equals ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood