( e ) Placing . Concrete shall be thoroughly compacted with suitable tools . When
necessary , openings shall be provided ... Wherever the temperature of the
surrounding air is below 40 degrees Fahrenheit , all concrete when placed in the
forms ...
( e ) Placing . Concrete shall be thoroughly compacted with suitable tools . When
necessary , openings shall be provided ... Wherever the temperature of the
surrounding air is below 40 degrees Fahrenheit , all concrete when placed in the
forms ...
Page 135
Any floor finish not placed monolithically with the floor slab shall not be included
as a part of the structural member . When the finish is placed monolithically with
the structural slab in buildings of the warehouse or industrial class , the over - all
...
Any floor finish not placed monolithically with the floor slab shall not be included
as a part of the structural member . When the finish is placed monolithically with
the structural slab in buildings of the warehouse or industrial class , the over - all
...
Page 241
Material or equipment necessary for the work Temporary under a building permit
may be placed or stored on public prop - Use of erty in the following locations :
Streets and ( a ) In Front of the Building Site . In the one - third portion Alleys of
the ...
Material or equipment necessary for the work Temporary under a building permit
may be placed or stored on public prop - Use of erty in the following locations :
Streets and ( a ) In Front of the Building Site . In the one - third portion Alleys of
the ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood