Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 64
Page 31
... portion thereof in which a G motor vehicle containing gasoline , distillate or other volatile , flammable liquid in its tank , is stored , repaired or kept . GARAGE , PRIVATE , is a building , or a portion of a build- ing , in which ...
... portion thereof in which a G motor vehicle containing gasoline , distillate or other volatile , flammable liquid in its tank , is stored , repaired or kept . GARAGE , PRIVATE , is a building , or a portion of a build- ing , in which ...
Page 123
... portion of a completed structure , when the conditions have been such as to leave reasonable doubt as to the adequacy of the structure to serve the purpose for which it is intended . When a load test is required , the member or portion ...
... portion of a completed structure , when the conditions have been such as to leave reasonable doubt as to the adequacy of the structure to serve the purpose for which it is intended . When a load test is required , the member or portion ...
Page 198
... portion thereof shall not exceed those set forth in Table No. 33 - A , except that where additional exit facilities ... portion thereof having an occupant load of 500 to 999 shall have not less than three exits . Buildings or portion ...
... portion thereof shall not exceed those set forth in Table No. 33 - A , except that where additional exit facilities ... portion thereof having an occupant load of 500 to 999 shall have not less than three exits . Buildings or portion ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood