Page 12
... Ramp , and Elevator Enclosures 3002 . 3003 . Other Vertical Openings CHAPTER 31 . Floor Construction .187 SEC . 3101 ... Ramps 3307 . Horizontal Exits 3308 . 12.
... Ramp , and Elevator Enclosures 3002 . 3003 . Other Vertical Openings CHAPTER 31 . Floor Construction .187 SEC . 3101 ... Ramps 3307 . Horizontal Exits 3308 . 12.
Page 201
... ramp conforming to the require- Ramps ments of this section may be used as an exit . Aisles need not conform to this section . ( b ) Width . The width of ramps shall be as required for corridors . ( c ) Slope . The slope of a ramp shall ...
... ramp conforming to the require- Ramps ments of this section may be used as an exit . Aisles need not conform to this section . ( b ) Width . The width of ramps shall be as required for corridors . ( c ) Slope . The slope of a ramp shall ...
Page 205
... Ramps . Every portion of a Group D occupancy , Di- vision 2 , in buildings of Types II , III , IV , and V housing bed- ridden patients , shall have access to a horizontal exit or a ramp leading to the exterior . ( f ) Doors . Exit doors ...
... Ramps . Every portion of a Group D occupancy , Di- vision 2 , in buildings of Types II , III , IV , and V housing bed- ridden patients , shall have access to a horizontal exit or a ramp leading to the exterior . ( f ) Doors . Exit doors ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood