Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 10
Page 226
... pipe housed and riveted . The curtain shall be held to the steel guides in the smoke pockets with substantial roller grips riveted or bolted to the side hem , not more than eighteen inches ( 18 " ) on center . Each roller grip shall be ...
... pipe housed and riveted . The curtain shall be held to the steel guides in the smoke pockets with substantial roller grips riveted or bolted to the side hem , not more than eighteen inches ( 18 " ) on center . Each roller grip shall be ...
Page 274
... Smoke Pipe Installation . The smoke pipe of warm air furnaces designed to burn solid fuel shall be at least eighteen inches ( 18 " ) from any combustible material , or such combus- tible material shall be protected by a covering of No ...
... Smoke Pipe Installation . The smoke pipe of warm air furnaces designed to burn solid fuel shall be at least eighteen inches ( 18 " ) from any combustible material , or such combus- tible material shall be protected by a covering of No ...
Page 305
... pipe inlets . For dry standpipes For exits For gas shut - off For seating capacity - required For stage curtains ... SMOKE Curtain to be tight for Pipes for Stacks for SMOKE PIPES SMOKEPROOF ENCLOSURE - REQUIRED Construction and design ...
... pipe inlets . For dry standpipes For exits For gas shut - off For seating capacity - required For stage curtains ... SMOKE Curtain to be tight for Pipes for Stacks for SMOKE PIPES SMOKEPROOF ENCLOSURE - REQUIRED Construction and design ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood