Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 59
Page 38
... space , streets , or yards , more than twenty feet ( 20 ' ) in width , extend along two sides of a building , the areas specified in Section 505 may be increased at a rate of 14 per cent for each foot by which the minimum width exceeds ...
... space , streets , or yards , more than twenty feet ( 20 ' ) in width , extend along two sides of a building , the areas specified in Section 505 may be increased at a rate of 14 per cent for each foot by which the minimum width exceeds ...
Page 72
... space of one - half inch ( 1⁄2 " ) shall be required between the wood flooring and adjoining walls to allow for expansion due to wetting . This space shall be covered by a molding secured to the wall only or masonry may be corbeled ...
... space of one - half inch ( 1⁄2 " ) shall be required between the wood flooring and adjoining walls to allow for expansion due to wetting . This space shall be covered by a molding secured to the wall only or masonry may be corbeled ...
Page 114
... space . It shall be used in specific locations , as follows : 1. In exterior or interior stud walls , at ceilings and floor levels . 2. In all stud walls and partitions , including furred spaces , so placed that the maximum dimension of ...
... space . It shall be used in specific locations , as follows : 1. In exterior or interior stud walls , at ceilings and floor levels . 2. In all stud walls and partitions , including furred spaces , so placed that the maximum dimension of ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood