Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 23
Page 14
... Stages and Platforms ... Stage Ventilators 3903 . 3904 . Gridirons Rooms Accessory to Stage Proscenium Walls 3905 . Stage Floors 3906 . Platforms 3907 . Stage Exits 3908 . 3909 . CHAPTER 40 . SEC . 4001 . 4002 . Miscellaneous Flame ...
... Stages and Platforms ... Stage Ventilators 3903 . 3904 . Gridirons Rooms Accessory to Stage Proscenium Walls 3905 . Stage Floors 3906 . Platforms 3907 . Stage Exits 3908 . 3909 . CHAPTER 40 . SEC . 4001 . 4002 . Miscellaneous Flame ...
Page 221
... stage floors shall be of Type I Stage construction except the part of the stage extending back from Floors and the full width of the proscenium opening , which may be constructed of steel or heavy timbers covered with a wood floor not ...
... stage floors shall be of Type I Stage construction except the part of the stage extending back from Floors and the full width of the proscenium opening , which may be constructed of steel or heavy timbers covered with a wood floor not ...
Page 305
... stage vent ducts 4004 3901 For live load - required SIAMESE CONNECTIONS For dry standpipes For wet standpipes SIDEWALKS Glass lights in Live load for design of Railing required around , when .. Required to be protected , when .... Space ...
... stage vent ducts 4004 3901 For live load - required SIAMESE CONNECTIONS For dry standpipes For wet standpipes SIDEWALKS Glass lights in Live load for design of Railing required around , when .. Required to be protected , when .... Space ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood