Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 16
Page 36
... stands , and amusement park structures not included within Group A and Divisions 1 , 2 and 3 , of Group B. 8 C 9 D 10 E 11 F 12 G 13 H 14 I 15 J Any building used for school purposes , | involving assemblage for instruc- tion ...
... stands , and amusement park structures not included within Group A and Divisions 1 , 2 and 3 , of Group B. 8 C 9 D 10 E 11 F 12 G 13 H 14 I 15 J Any building used for school purposes , | involving assemblage for instruc- tion ...
Page 87
... Stand- ard Specifications for Sand - Lime Building Brick , " ( C73-39 ) ; or A.S.T.M. “ Standard Specifications for Concrete Building Brick , ” ( C55-37 ) . When in contact with the ground or where severe frost action occurs in the ...
... Stand- ard Specifications for Sand - Lime Building Brick , " ( C73-39 ) ; or A.S.T.M. “ Standard Specifications for Concrete Building Brick , ” ( C55-37 ) . When in contact with the ground or where severe frost action occurs in the ...
Page 216
... stand- pipe shall be installed for each additional ten thousand square feet ( 10,000 sq . ft . ) or fraction thereof . ( d ) Location . Standpipes shall be located within stairway enclosures or as near such stairways as possible or ...
... stand- pipe shall be installed for each additional ten thousand square feet ( 10,000 sq . ft . ) or fraction thereof . ( d ) Location . Standpipes shall be located within stairway enclosures or as near such stairways as possible or ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood