Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 79
Page 132
... steel Beams with no web reinforcement , but with special anchorage of longitudinal steel Beams with properly designed web re- inforcement but without special an- chorage of longitudinal steel Beams with properly designed web re ...
... steel Beams with no web reinforcement , but with special anchorage of longitudinal steel Beams with properly designed web re- inforcement but without special an- chorage of longitudinal steel Beams with properly designed web re ...
Page 175
... steel sheets or plates constructed to act integrally with steel joists , studs , or other steel supporting members shall not extend more than 20 times the thickness of such sheet or plate on each side of the point or points of fixation ...
... steel sheets or plates constructed to act integrally with steel joists , studs , or other steel supporting members shall not extend more than 20 times the thickness of such sheet or plate on each side of the point or points of fixation ...
Page 236
... steel joists or steel floors protected with fire - resistive materials of the kind and thickness set forth in Table No. 43 - C . Except in the case of steel - joisted construction , all reinforcing , tie rods and supporting structural ...
... steel joists or steel floors protected with fire - resistive materials of the kind and thickness set forth in Table No. 43 - C . Except in the case of steel - joisted construction , all reinforcing , tie rods and supporting structural ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood