... stories allowed times 15 plus twenty - five feet ( 25 ' ) , nor the limitation of Part V ( Types of Construction ) . The limits set forth in Table No. 5 - D may be increased in height by one story in Type III , IV , and V buildings of ...
... stories allowed times 15 plus twenty - five feet ( 25 ' ) , nor the limitation of Part V ( Types of Construction ) . The limits set forth in Table No. 5 - D may be increased in height by one story in Type III , IV , and V buildings of ...
Page 89
... story walls of a building not exceeding three stories or thirty - five feet ( 35 ' ) in height or the walls of a one - story building may have a wall thick- ness equal to the least dimensions as set forth in Table No. 24 - C . 2. The ...
... story walls of a building not exceeding three stories or thirty - five feet ( 35 ' ) in height or the walls of a one - story building may have a wall thick- ness equal to the least dimensions as set forth in Table No. 24 - C . 2. The ...
Page 113
... stories or less shall consist of not less than two - inch bv four - inch ( 2 " x4 " ) studs ; for buildings of three stories . the studding shall be not less than three - inch by four- inch ( 3 " x4 " ) or two - inch by six - inch ( 2 ...
... stories or less shall consist of not less than two - inch bv four - inch ( 2 " x4 " ) studs ; for buildings of three stories . the studding shall be not less than three - inch by four- inch ( 3 " x4 " ) or two - inch by six - inch ( 2 ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood