Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 44
Page 43
... street , not less than Property twenty feet ( 20 ' ) in width , in which front shall be located the main entrance of such building . Exterior walls or parts of walls except on street fronts which are less than five feet ( 5 ′ ) from ...
... street , not less than Property twenty feet ( 20 ' ) in width , in which front shall be located the main entrance of such building . Exterior walls or parts of walls except on street fronts which are less than five feet ( 5 ′ ) from ...
Page 56
... street fronts of Group H occupancies which are less than three feet ( 3 ' ) from adjacent property lines , shall have no openings therein , shall be of not less than one - hour fire - resistive con- struction and shall be constructed as ...
... street fronts of Group H occupancies which are less than three feet ( 3 ' ) from adjacent property lines , shall have no openings therein , shall be of not less than one - hour fire - resistive con- struction and shall be constructed as ...
Page 241
... street , alley or public sidewalk , nor shall any work be performed except in accordance with the provisions of this Chapter . No person shall perform any work on any building or struc- ture , if by so doing he endangers pedestrians on ...
... street , alley or public sidewalk , nor shall any work be performed except in accordance with the provisions of this Chapter . No person shall perform any work on any building or struc- ture , if by so doing he endangers pedestrians on ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood