Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 88
Page 19
... structure , such building or structure shall be made to conform to the requirements for new buildings or structures . ( c ) Additions , Alterations , and Repairs : 25 to 50 Per Cent . Additions , alterations , and repairs exceeding 25 ...
... structure , such building or structure shall be made to conform to the requirements for new buildings or structures . ( c ) Additions , Alterations , and Repairs : 25 to 50 Per Cent . Additions , alterations , and repairs exceeding 25 ...
Page 20
... structure is constructed . ( e ) Non - Structural Alterations and Repairs : 25 Per Cent or Less . Alterations or repairs , not exceeding 25 per cent of the value of an existing building or structure , which are non - structural and do ...
... structure is constructed . ( e ) Non - Structural Alterations and Repairs : 25 Per Cent or Less . Alterations or repairs , not exceeding 25 per cent of the value of an existing building or structure , which are non - structural and do ...
Page 123
... structure . The tests shall be made , when ordered by the Building Official , by the owner or his authorized representative and no responsibility for the expense of these tests shall attach to the Building Department . All such tests ...
... structure . The tests shall be made , when ordered by the Building Official , by the owner or his authorized representative and no responsibility for the expense of these tests shall attach to the Building Department . All such tests ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood