Page 117
... temperature for not less than 15 days , after which they shall be dried in a room at a relative humidity of 30 per cent or less and a temperature of 70 to 85 degrees Fahrenheit for three days and with forced circulation of air , making ...
... temperature for not less than 15 days , after which they shall be dried in a room at a relative humidity of 30 per cent or less and a temperature of 70 to 85 degrees Fahrenheit for three days and with forced circulation of air , making ...
Page 126
... temperature of the surround- ing air is below 40 degrees Fahrenheit , all concrete when placed in the forms shall have a temperature of between 60 and 90 degrees Fahrenheit and shall be maintained at a tem- perature of not less than 50 ...
... temperature of the surround- ing air is below 40 degrees Fahrenheit , all concrete when placed in the forms shall have a temperature of between 60 and 90 degrees Fahrenheit and shall be maintained at a tem- perature of not less than 50 ...
Page 239
... temperature of a heat- actuated device reaches 165 degrees Fahrenheit or 50 degrees above maximum room temperature under normal conditions . Heat - actuated devices shall be installed , one on each side of the wall at the top of the ...
... temperature of a heat- actuated device reaches 165 degrees Fahrenheit or 50 degrees above maximum room temperature under normal conditions . Heat - actuated devices shall be installed , one on each side of the wall at the top of the ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood