Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 54
Page 20
... Tests tural additions , alterations , or repairs , when approved by the Building Official , may be made with the ... tests as proof of compliance to be made at the expense of the owner or his agent by an approved agency . Test methods ...
... Tests tural additions , alterations , or repairs , when approved by the Building Official , may be made with the ... tests as proof of compliance to be made at the expense of the owner or his agent by an approved agency . Test methods ...
Page 116
... tests to be made as specified in this section . ( b ) Test Samples . Each test series shall consist of a mini- mum of nine samples . One test series shall be required for each type and brand of glue to be used and each species of wood ...
... tests to be made as specified in this section . ( b ) Test Samples . Each test series shall consist of a mini- mum of nine samples . One test series shall be required for each type and brand of glue to be used and each species of wood ...
Page 123
... tests shall be made , when ordered by the Building Official , by the owner or his authorized representative and no responsibility for the expense of these tests shall attach to the Building Department . All such tests shall be made by ...
... tests shall be made , when ordered by the Building Official , by the owner or his authorized representative and no responsibility for the expense of these tests shall attach to the Building Department . All such tests shall be made by ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood