Page 184
... inches ( 24 ′′ ) apart horizontally and not more than twelve inches ( 12 " ) apart vertically . Veneer ties shall be attached to a continuous horizontal tie not less in thickness than No. 8 W & M gauge wire and em- bedded in a ...
... inches ( 24 ′′ ) apart horizontally and not more than twelve inches ( 12 " ) apart vertically . Veneer ties shall be attached to a continuous horizontal tie not less in thickness than No. 8 W & M gauge wire and em- bedded in a ...
Page 213
... twelve inches ( 12 " ) of the fireplace opening shall project more than one- eighth inch ( % " ) for each one - inch ... inches ( 6 " ) unless such recess meets the requirements for fireplaces . The surface of the recess shall be of fire ...
... twelve inches ( 12 " ) of the fireplace opening shall project more than one- eighth inch ( % " ) for each one - inch ... inches ( 6 " ) unless such recess meets the requirements for fireplaces . The surface of the recess shall be of fire ...
Page 226
Pacific Coast Building Officials Conference, International Conference of Building Officials. Operating Equipment inches ( 8 " ) and shall overlap the top and sides of the proscenium opening at least twelve inches ( 12 " ) . Six - inch ...
Pacific Coast Building Officials Conference, International Conference of Building Officials. Operating Equipment inches ( 8 " ) and shall overlap the top and sides of the proscenium opening at least twelve inches ( 12 " ) . Six - inch ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood