Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 44
Page 60
... unless such storage or handling shall com- ply with the N. B. F. U. " Fire Prevention Ordinance , " 1943 . Sec . 1509. When storage space termed in this Code a private garage is provided in any building of mixed occupancies , such ...
... unless such storage or handling shall com- ply with the N. B. F. U. " Fire Prevention Ordinance , " 1943 . Sec . 1509. When storage space termed in this Code a private garage is provided in any building of mixed occupancies , such ...
Page 75
... unless otherwise provided , because of loca- of Structural tion as in Part IV or Occupancy as in Part III , or as required in Members this Chapter . All members carrying masonry in buildings over one story in height shall be fire ...
... unless otherwise provided , because of loca- of Structural tion as in Part IV or Occupancy as in Part III , or as required in Members this Chapter . All members carrying masonry in buildings over one story in height shall be fire ...
Page 179
... unless such footing or foundation is first properly underpinned or protected against settlement . Any person making or causing an excavation to be made to a depth of twelve feet ( 12 ′ ) , or less , below the grade , shall pro- tect the ...
... unless such footing or foundation is first properly underpinned or protected against settlement . Any person making or causing an excavation to be made to a depth of twelve feet ( 12 ′ ) , or less , below the grade , shall pro- tect the ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood