Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 81
Page 6
Page 602 . Construction , Height and Area Allowable 603 . Location on Property
604 . Exit Facilities 605 . Light , Ventilation , and Sanitation 606 . Enclosure of
Vertical Openings 607 . Fire - Extinguishing Apparatus 608 . Special Hazards
609 .
Page 602 . Construction , Height and Area Allowable 603 . Location on Property
604 . Exit Facilities 605 . Light , Ventilation , and Sanitation 606 . Enclosure of
Vertical Openings 607 . Fire - Extinguishing Apparatus 608 . Special Hazards
609 .
Page 7
Enclosure of Vertical Openings 1107 . Fire - Extinguishing Apparatus 1108 .
Special Hazards CHAPTER 12 . Requirements for Group G Occupancies 54 SEC
. 1201 . Group G Occupancies Defined 1202 . Construction , Height and Area ...
Enclosure of Vertical Openings 1107 . Fire - Extinguishing Apparatus 1108 .
Special Hazards CHAPTER 12 . Requirements for Group G Occupancies 54 SEC
. 1201 . Group G Occupancies Defined 1202 . Construction , Height and Area ...
Page 264
All bracing systems both horizontal and vertical shall transmit all forces to the
resisting members and shall be of sufficient extent and detail to resist the
horizontal forces provided for in this Section and shall be located symmetrically
about the ...
All bracing systems both horizontal and vertical shall transmit all forces to the
resisting members and shall be of sufficient extent and detail to resist the
horizontal forces provided for in this Section and shall be located symmetrically
about the ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood