Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 81
Page 6
... Vertical Openings Fire - Extinguishing Apparatus 608 . Special Hazards 609 . Exceptions and Deviations CHAPTER 7 . SEC . 701 . Page 702 . Requirements for Group B Occupancies 42 Group B Occupancies Defined Construction , Height and Area ...
... Vertical Openings Fire - Extinguishing Apparatus 608 . Special Hazards 609 . Exceptions and Deviations CHAPTER 7 . SEC . 701 . Page 702 . Requirements for Group B Occupancies 42 Group B Occupancies Defined Construction , Height and Area ...
Page 7
... Vertical Openings 1107. Fire - Extinguishing Apparatus 1108 . CHAPTER 12 . SEC . 1201 . Special Hazards Requirements for Group G Occupancies 54 Group G Occupancies Defined 1202. Construction , Height and Area 1203 . 1204 . 1205 . 1206 ...
... Vertical Openings 1107. Fire - Extinguishing Apparatus 1108 . CHAPTER 12 . SEC . 1201 . Special Hazards Requirements for Group G Occupancies 54 Group G Occupancies Defined 1202. Construction , Height and Area 1203 . 1204 . 1205 . 1206 ...
Page 264
... vertical designed live load . The force shall be assumed to come from any horizontal direction . All bracing systems both horizontal and vertical shall trans- mit all forces to the resisting members and shall be of sufficient extent and ...
... vertical designed live load . The force shall be assumed to come from any horizontal direction . All bracing systems both horizontal and vertical shall trans- mit all forces to the resisting members and shall be of sufficient extent and ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood