Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 84
Page 70
... walls may be used . Exterior walls shall be of fire - resistive construction . Inner court walls shall be of incombustible materials or pro- tected solid wood . Roof construction shall be of wood , or incombustible materials . Floors ...
... walls may be used . Exterior walls shall be of fire - resistive construction . Inner court walls shall be of incombustible materials or pro- tected solid wood . Roof construction shall be of wood , or incombustible materials . Floors ...
Page 80
Pacific Coast Building Officials Conference, International Conference of Building Officials. Retaining Walls Exterior Walls and Wall Coverings Wall Coverings Foundation walls and all other walls used as retaining walls in connection with ...
Pacific Coast Building Officials Conference, International Conference of Building Officials. Retaining Walls Exterior Walls and Wall Coverings Wall Coverings Foundation walls and all other walls used as retaining walls in connection with ...
Page 233
... walls or partitions the required effective thick- ness of wall shall be measured from two inches ( 2 " ) back along the member from the end in the wall , to the opposite face of the wall . Where such members project into hollow walls ...
... walls or partitions the required effective thick- ness of wall shall be measured from two inches ( 2 " ) back along the member from the end in the wall , to the opposite face of the wall . Where such members project into hollow walls ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood