Page 56
... water- closet compartments , and other similar rooms shall not be less than three square feet ( 3 sq . ft . ) , unless adequate mechanical ventilation is provided . Not less than one - half such area shall be openable . Required windows ...
... water- closet compartments , and other similar rooms shall not be less than three square feet ( 3 sq . ft . ) , unless adequate mechanical ventilation is provided . Not less than one - half such area shall be openable . Required windows ...
Page 58
... water - closet compartments , and other similar rooms shall not be less than three square feet ( 3 sq . ft . ) . Required windows shall open on a court , yard , or street either directly or through a porch with a minimum clear height of ...
... water - closet compartments , and other similar rooms shall not be less than three square feet ( 3 sq . ft . ) . Required windows shall open on a court , yard , or street either directly or through a porch with a minimum clear height of ...
Page 224
... water closet and lavatory . CHAPTER 41 - PROSCENIUM CURTAINS Sec . 4101. Proscenium curtains 224 Sections 4004-4007 UNIFORM BUILDING CODE.
... water closet and lavatory . CHAPTER 41 - PROSCENIUM CURTAINS Sec . 4101. Proscenium curtains 224 Sections 4004-4007 UNIFORM BUILDING CODE.
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood