Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 81
Page 23
Construction , Height and Area Allowable 1103. Location on Property 1104 . Exit Facilities 1105. Light , Ventilation , and Sanitation 1106. Enclosure of Vertical Openings 1107. Fire - Extinguishing Apparatus 1108.
Construction , Height and Area Allowable 1103. Location on Property 1104 . Exit Facilities 1105. Light , Ventilation , and Sanitation 1106. Enclosure of Vertical Openings 1107. Fire - Extinguishing Apparatus 1108.
Page 25
Height Allowable 2003. Area Allowable 2004. Foundations 2005. Exterior and Inner Court Walls 2006. Partitions 2007. Enclosure of Vertical Openings 2008. Structural Framework 2009. Fire - Protection of Structural Members 2010 .
Height Allowable 2003. Area Allowable 2004. Foundations 2005. Exterior and Inner Court Walls 2006. Partitions 2007. Enclosure of Vertical Openings 2008. Structural Framework 2009. Fire - Protection of Structural Members 2010 .
Page 128
Allowable Unit Stresses ( Cont'd . ) the species listed in Table No. 25 - A , shall not exceed the values therein given . For species and grades not given in Table No. 25 - A , the working stresses therefor shall be established by the ...
Allowable Unit Stresses ( Cont'd . ) the species listed in Table No. 25 - A , shall not exceed the values therein given . For species and grades not given in Table No. 25 - A , the working stresses therefor shall be established by the ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone