Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 82
Page 23
... Allowable Location on Property Exit Facilities Light , Ventilation , and Sanitation Enclosure of Vertical Openings 1107. Fire - Extinguishing Apparatus 1108 . CHAPTER 12 . SEC . 1201 . 1202 . 1203 . 1204 . 1205 . Special Hazards ...
... Allowable Location on Property Exit Facilities Light , Ventilation , and Sanitation Enclosure of Vertical Openings 1107. Fire - Extinguishing Apparatus 1108 . CHAPTER 12 . SEC . 1201 . 1202 . 1203 . 1204 . 1205 . Special Hazards ...
Page 25
... Allowable 2003 . Area Allowable 2004 . Foundations 2005. Exterior and Inner Court Walls 2006 . 2007 . 2008 . 2009 . 2010 . Partitions Enclosure of Vertical Openings Structural Framework Fire - Protection of Structural Members Floor ...
... Allowable 2003 . Area Allowable 2004 . Foundations 2005. Exterior and Inner Court Walls 2006 . 2007 . 2008 . 2009 . 2010 . Partitions Enclosure of Vertical Openings Structural Framework Fire - Protection of Structural Members Floor ...
Page 128
... allowable unit stresses named in this Sec- tion are assigned for lumber used in continuously dry locations . For the condition of occasionally wet and quickly dried , the allowable unit stresses of Table No. 25 - A shall be multiplied ...
... allowable unit stresses named in this Sec- tion are assigned for lumber used in continuously dry locations . For the condition of occasionally wet and quickly dried , the allowable unit stresses of Table No. 25 - A shall be multiplied ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood