Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 15
Page 16
... Class A Members For codes desired to be sent via air mail enclose $ 1.50 per copy ordered . Regular parcel post charges are prepaid . Several chapters of the Uniform Building Code are reprinted as pamphlets , including the chapters on ...
... Class A Members For codes desired to be sent via air mail enclose $ 1.50 per copy ordered . Regular parcel post charges are prepaid . Several chapters of the Uniform Building Code are reprinted as pamphlets , including the chapters on ...
Page 66
... Class 2 shall be the main exercise rooms of gymnasiums and the capacity unit therefor shall be fifteen square feet ( 15 sq . ft . ) . Class 3 shall be general class rooms , recreation rooms , and similar rooms and the capacity unit ...
... Class 2 shall be the main exercise rooms of gymnasiums and the capacity unit therefor shall be fifteen square feet ( 15 sq . ft . ) . Class 3 shall be general class rooms , recreation rooms , and similar rooms and the capacity unit ...
Page 259
... Class C Asphalt , Rag Felt , Sheet Roofing and Shingles , " published by the Underwriters ' Laboratories , Incorporated , edi- tion of 1941 . 3. Method of Laying . Where there is not a ceiling under- neath , a layer of unsaturated ...
... Class C Asphalt , Rag Felt , Sheet Roofing and Shingles , " published by the Underwriters ' Laboratories , Incorporated , edi- tion of 1941 . 3. Method of Laying . Where there is not a ceiling under- neath , a layer of unsaturated ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood