Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 5
Page 62
... occupancies shall be : Division 1. Any assembly building with a working stage and a seating capacity of less than ... 3. Any assembly building without a working stage and a seating capacity of less than 100 in any one room . Division 4 ...
... occupancies shall be : Division 1. Any assembly building with a working stage and a seating capacity of less than ... 3. Any assembly building without a working stage and a seating capacity of less than 100 in any one room . Division 4 ...
Page 63
... Division 4. structures to be re - inspected at least once every six months . Sec . 703. All buildings housing Group B occupancies ... 3 , except on street fronts , which are less than ten feet ( 10 ' ) from ... Division 1 , 2 and 3 occupancies ...
... Division 4. structures to be re - inspected at least once every six months . Sec . 703. All buildings housing Group B occupancies ... 3 , except on street fronts , which are less than ten feet ( 10 ' ) from ... Division 1 , 2 and 3 occupancies ...
Page 64
... 3. AISLES . Aisles not less than three feet six inches ( 3'6 " ) wide shall ... Division 4 amusement structures shall be provided as specified in Chapter 33 ... occupancies customarily used by human beings and all dressing rooms shall be ...
... 3. AISLES . Aisles not less than three feet six inches ( 3'6 " ) wide shall ... Division 4 amusement structures shall be provided as specified in Chapter 33 ... occupancies customarily used by human beings and all dressing rooms shall be ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood