Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 3
Page 27
... Fastening 2526. Fire Stops 2527 . Foundation Ventilation 2528 . Wood Diaphragms 2529 . Termite Provisions CHAPTER 26. Reinforced Concrete SEC . 2601 . ( Quality and Design ) . Quality 2602. Design 2603 . Definitions 2604 . Materials ...
... Fastening 2526. Fire Stops 2527 . Foundation Ventilation 2528 . Wood Diaphragms 2529 . Termite Provisions CHAPTER 26. Reinforced Concrete SEC . 2601 . ( Quality and Design ) . Quality 2602. Design 2603 . Definitions 2604 . Materials ...
Page 141
... Fastening be adequately resisted . The sheathing and the sub - flooring shall be fastened to the studs , rafters or joists with nails which shall be in length at least two and one - half times the nominal thick- ness of the sheathing or ...
... Fastening be adequately resisted . The sheathing and the sub - flooring shall be fastened to the studs , rafters or joists with nails which shall be in length at least two and one - half times the nominal thick- ness of the sheathing or ...
Page 257
... fastening is directly opposite each door hanger when door is in a closed position . Hangers supporting doors shall be fastened to the door with not less than three one- half inch ( 1⁄2 " ) bolts extending through the door . Latches for ...
... fastening is directly opposite each door hanger when door is in a closed position . Hangers supporting doors shall be fastened to the door with not less than three one- half inch ( 1⁄2 " ) bolts extending through the door . Latches for ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood