... FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES Sec . 1601. ( a ) Fire Zones Defined . For the purpose of this Code , the entire city is hereby declared to be and is hereby established a Fire District and said Fire District shall be ...
... FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES Sec . 1601. ( a ) Fire Zones Defined . For the purpose of this Code , the entire city is hereby declared to be and is hereby established a Fire District and said Fire District shall be ...
Page 258
... Fire Underwriters , recommended by the National Fire Protection Association , Edition of January , 1939.1 All fire doors shall be so hung that when closed they will fit tightly into place against the wall or frame so as to prove an ...
... Fire Underwriters , recommended by the National Fire Protection Association , Edition of January , 1939.1 All fire doors shall be so hung that when closed they will fit tightly into place against the wall or frame so as to prove an ...
Page 300
... FIRE Classification of materials for resistance to ( see Chapter 43 ) Extinguishing ( see FIRE EXTINGUISHING apparatus APPARATUS ) Separations required - for certain occupancies Standards for resistance of ( see Chapters 42 and 43 ) ...
... FIRE Classification of materials for resistance to ( see Chapter 43 ) Extinguishing ( see FIRE EXTINGUISHING apparatus APPARATUS ) Separations required - for certain occupancies Standards for resistance of ( see Chapters 42 and 43 ) ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood