Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 28
Page 37
... Inspections Required . The Building Inspector Inspection shall inspect or cause to be inspected at various intervals dur- and ing the erection , construction , enlarging , alteration , repairing , Registered moving , demolition ...
... Inspections Required . The Building Inspector Inspection shall inspect or cause to be inspected at various intervals dur- and ing the erection , construction , enlarging , alteration , repairing , Registered moving , demolition ...
Page 38
... inspection on the following types of work : 1. Reinforced Concrete . On reinforced concrete work when the design is based on an f ' , in excess of 2,000 pounds . 2. Masonry . On masonry when the design is based on unit stresses in ...
... inspection on the following types of work : 1. Reinforced Concrete . On reinforced concrete work when the design is based on an f ' , in excess of 2,000 pounds . 2. Masonry . On masonry when the design is based on unit stresses in ...
Page 300
... INSPECTION Certificate of Compliance required when 205 Made when 206 Required when . 204 FINES FOR VIOLATIONS 306 FIRE Classification of materials for resistance to ( see Chapter 43 ) Extinguishing ( see FIRE EXTINGUISHING apparatus ...
... INSPECTION Certificate of Compliance required when 205 Made when 206 Required when . 204 FINES FOR VIOLATIONS 306 FIRE Classification of materials for resistance to ( see Chapter 43 ) Extinguishing ( see FIRE EXTINGUISHING apparatus ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood