Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 84
Page 85
... Type IV construction in excess of four hundred square feet ( 400 sq . ft . ) in floor area nor any building of Type V construction already erected in Fire Zone No. 1 shall hereafter be altered , raised , enlarged , added to or moved ...
... Type IV construction in excess of four hundred square feet ( 400 sq . ft . ) in floor area nor any building of Type V construction already erected in Fire Zone No. 1 shall hereafter be altered , raised , enlarged , added to or moved ...
Page 87
... Type of Construction , it shall comply with all of the requirements for that Type of Construction , as specified in this Code . No building or portion thereof shall be required to conform to the details of a Type of Construction higher ...
... Type of Construction , it shall comply with all of the requirements for that Type of Construction , as specified in this Code . No building or portion thereof shall be required to conform to the details of a Type of Construction higher ...
Page 103
... Type I , II , III or IV construction shall be considered to be of Type V. Sec . 2202. Type V buildings shall not exceed a height of Height thirty - eight feet ( 38 ' ) ; provided that the height of a building Allowable erected on ...
... Type I , II , III or IV construction shall be considered to be of Type V. Sec . 2202. Type V buildings shall not exceed a height of Height thirty - eight feet ( 38 ' ) ; provided that the height of a building Allowable erected on ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood