... types of construction or materials offered Materials as an alternate for the types of construction or materials re- and Types quired by this Code , but such alternate types of construction of Con- or materials to be given consideration ...
... types of construction or materials offered Materials as an alternate for the types of construction or materials re- and Types quired by this Code , but such alternate types of construction of Con- or materials to be given consideration ...
Page 85
... construction in excess of four hundred square feet ( 400 sq . ft . ) in floor area nor any building of Type V construction ... Types of Construction as defined in this Code and shall meet the requirements of this Section . ( b ) Limitation of ...
... construction in excess of four hundred square feet ( 400 sq . ft . ) in floor area nor any building of Type V construction ... Types of Construction as defined in this Code and shall meet the requirements of this Section . ( b ) Limitation of ...
Page 87
... Types of Construction . In order that a building may be classed in any specific Type of Construction , it shall comply with all of the requirements for that Type of Construction , as specified in this Code . No building or portion ...
... Types of Construction . In order that a building may be classed in any specific Type of Construction , it shall comply with all of the requirements for that Type of Construction , as specified in this Code . No building or portion ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood