Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 7
Page 127
... White 1100 1 , 1941 Longleaf So. Pine Select Structural 1450 2000 1005 Prime Structural 1300 1800 100 Merchantable ... White 1600f Oak , Red and White 1400f Oak , Red and White 1200f Oak , Red and White 1800 120 1600 120 1400 120 500 ...
... White 1100 1 , 1941 Longleaf So. Pine Select Structural 1450 2000 1005 Prime Structural 1300 1800 100 Merchantable ... White 1600f Oak , Red and White 1400f Oak , Red and White 1200f Oak , Red and White 1800 120 1600 120 1400 120 500 ...
Page 272
... white finish , mixed in the proportion of not less than one part gypsum gauging plaster or Keene's cement to three parts lime putty by volume , or a prepared gypsum trowel finish . 2. Sand - float finish , mixed in the proportion of one ...
... white finish , mixed in the proportion of not less than one part gypsum gauging plaster or Keene's cement to three parts lime putty by volume , or a prepared gypsum trowel finish . 2. Sand - float finish , mixed in the proportion of one ...
Page 273
... white finish , mixed in the proportion of not less than one part gypsum gauging plaster or Keene's cement to three parts lime putty by volume . 4. Keene's cement finish , mixed in the proportions of three parts Keene's cement to one ...
... white finish , mixed in the proportion of not less than one part gypsum gauging plaster or Keene's cement to three parts lime putty by volume . 4. Keene's cement finish , mixed in the proportions of three parts Keene's cement to one ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood