... Zones . " Whenever in such ordinance creating and establishing fire zones , reference is made to any fire zone , it shall be construed to mean one of the three fire zones desig- nated and referred to in this Chapter . ( b ) Buildings ...
... Zones . " Whenever in such ordinance creating and establishing fire zones , reference is made to any fire zone , it shall be construed to mean one of the three fire zones desig- nated and referred to in this Chapter . ( b ) Buildings ...
Page 85
... Zone No. 1 . 5. Such building may be demolished . ( e ) Occupancies Prohibited . No Group E occupancies except garages shall be permitted in Fire Zone No. 1 . Sec . 1603. ( a ) General . Buildings or structures hereafter Restrictions ...
... Zone No. 1 . 5. Such building may be demolished . ( e ) Occupancies Prohibited . No Group E occupancies except garages shall be permitted in Fire Zone No. 1 . Sec . 1603. ( a ) General . Buildings or structures hereafter Restrictions ...
Page 285
... zones . The values given " C " are minimum and should be adopted in locations not subject to frequent seismic dis- turbances as shown in Zone 1. For locations in Zone 2 , " C " should be doubled . For locations in Zone 3 , " C " should ...
... zones . The values given " C " are minimum and should be adopted in locations not subject to frequent seismic dis- turbances as shown in Zone 1. For locations in Zone 2 , " C " should be doubled . For locations in Zone 3 , " C " should ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood