Page 132
O + q cos O WHERE n = safe load in pounds on bolt . p = safe load on bolt parallel to grain as set forth in Table No. ... 25 - B - HOLDING POWER OF BOLTS Loads Parallel to Grain ( p ) Diameter of Bolt in Inches Length of Bolt in main ...
O + q cos O WHERE n = safe load in pounds on bolt . p = safe load on bolt parallel to grain as set forth in Table No. ... 25 - B - HOLDING POWER OF BOLTS Loads Parallel to Grain ( p ) Diameter of Bolt in Inches Length of Bolt in main ...
Page 133
( d ) Bolts in Other Species of Wood . For species of wood Bolted other than those set forth in Tables No. 25 - B and 25 - C , Joints bolt values shall be derived in accordance with the principles ( Contd . ) stated in " Wood Handbook ...
( d ) Bolts in Other Species of Wood . For species of wood Bolted other than those set forth in Tables No. 25 - B and 25 - C , Joints bolt values shall be derived in accordance with the principles ( Contd . ) stated in " Wood Handbook ...
Page 134
Timber Connectors seven times the bolt diameter for softwoods and five times for hardwoods . ... Joints wherein timber connectors are used with bolts to transmit stresses between structural or load - bearing members shall be designed in ...
Timber Connectors seven times the bolt diameter for softwoods and five times for hardwoods . ... Joints wherein timber connectors are used with bolts to transmit stresses between structural or load - bearing members shall be designed in ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone