Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 47
Page 114
... Cement - Lime Mortar . Cement - lime mortar shall be composed , by volume , of one part portland cement , one - half part lime putty , and not more than four and one - half parts of mortar sand . ( q ) Cement Mortar . Cement mortar ...
... Cement - Lime Mortar . Cement - lime mortar shall be composed , by volume , of one part portland cement , one - half part lime putty , and not more than four and one - half parts of mortar sand . ( q ) Cement Mortar . Cement mortar ...
Page 272
... cement and four pounds of fiber to one cubic yard ( 1 cu . yd . ) of sand . 4. Portland Cement Plaster . For three - coat work , the first two coats shall be as required for the first two coats of exterior work . ( b ) Finish Coats for ...
... cement and four pounds of fiber to one cubic yard ( 1 cu . yd . ) of sand . 4. Portland Cement Plaster . For three - coat work , the first two coats shall be as required for the first two coats of exterior work . ( b ) Finish Coats for ...
Page 273
... cement plaster mixed in proportion of one part portland cement to not more than two and one - half parts of lime putty and not more than four parts of sand by volume . 3. Smooth white finish , mixed in the proportion of not less than ...
... cement plaster mixed in proportion of one part portland cement to not more than two and one - half parts of lime putty and not more than four parts of sand by volume . 3. Smooth white finish , mixed in the proportion of not less than ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood