Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 59
Page 110
... cent 0 per cent 5 per cent .10 per cent .15 per cent .20 per cent Live Load Reductions for Manufacturing Buildings , 0 per cent Carrying 2 floors and roof .. Carrying 3 floors and roof .. Carrying 4 floors and roof .. Carrying 5 or more ...
... cent 0 per cent 5 per cent .10 per cent .15 per cent .20 per cent Live Load Reductions for Manufacturing Buildings , 0 per cent Carrying 2 floors and roof .. Carrying 3 floors and roof .. Carrying 4 floors and roof .. Carrying 5 or more ...
Page 119
... cent by weight of wood chips , shavings or fiber ) 1,000 Gypsum fiber concrete ( containing not more than 121⁄2 per cent by weight of wood chips , shavings or fiber ) .... 500 Compressive tests shall be made on cylinders six inches ( 6 ...
... cent by weight of wood chips , shavings or fiber ) 1,000 Gypsum fiber concrete ( containing not more than 121⁄2 per cent by weight of wood chips , shavings or fiber ) .... 500 Compressive tests shall be made on cylinders six inches ( 6 ...
Page 217
... cent . For buildings four stories or more in height the allowable areas shall be decreased two per cent per floor for each floor above the third floor to and including the eighth floor and shall be decreased one per cent for each addi ...
... cent . For buildings four stories or more in height the allowable areas shall be decreased two per cent per floor for each floor above the third floor to and including the eighth floor and shall be decreased one per cent for each addi ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood