Page 227
... chimneys shall have an open- ing opposite the clean - out on the chimney for the purpose of cleaning the flue . When such chimneys are used with fireplaces , they shall be supported by a metal plate embedded in mortar at the throat of ...
... chimneys shall have an open- ing opposite the clean - out on the chimney for the purpose of cleaning the flue . When such chimneys are used with fireplaces , they shall be supported by a metal plate embedded in mortar at the throat of ...
Page 228
... chimney as specified in Section 3704 . All fireplaces and chimney breasts shall have trimmer arches or other approved fire - resistive construction supporting hearths . The arches and hearths shall be not less than twenty inches ( 20 ...
... chimney as specified in Section 3704 . All fireplaces and chimney breasts shall have trimmer arches or other approved fire - resistive construction supporting hearths . The arches and hearths shall be not less than twenty inches ( 20 ...
Page 230
... chimney as specified in Section 3701 . In the kitchen of every building hereafter erected there shall be provided a chimney as provided in Section 3701 , a vent as provided in Section 3703 or in lieu of such chimney or vent , when ...
... chimney as specified in Section 3701 . In the kitchen of every building hereafter erected there shall be provided a chimney as provided in Section 3701 , a vent as provided in Section 3703 or in lieu of such chimney or vent , when ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood