Page 29
... Chimneys and Heating Apparatus .... Chimneys Smokestacks 3703. Gas Vents 3704 . Patent Chimneys 3705. Smoke Pipes and Thimbles 3706 . Fireplaces 3707 . Warm Air Furnaces 3708. Low Pressure Steam Heating Plants 3709 . 3710 . Boilers ...
... Chimneys and Heating Apparatus .... Chimneys Smokestacks 3703. Gas Vents 3704 . Patent Chimneys 3705. Smoke Pipes and Thimbles 3706 . Fireplaces 3707 . Warm Air Furnaces 3708. Low Pressure Steam Heating Plants 3709 . 3710 . Boilers ...
Page 226
... chimneys may be used , except for oil burners , when complying with the requirements of this Code . All patent chimneys shall be constructed with a flue lining enclosed in a metal outer casing which is so arranged as to provide not less ...
... chimneys may be used , except for oil burners , when complying with the requirements of this Code . All patent chimneys shall be constructed with a flue lining enclosed in a metal outer casing which is so arranged as to provide not less ...
Page 227
... chimneys shall be built up from the floor level on which they are used and in no case shall a stove pipe enter the bottom of a patent chimney . When such chimneys are erected on the outside of a build- ing they shall be supported by a ...
... chimneys shall be built up from the floor level on which they are used and in no case shall a stove pipe enter the bottom of a patent chimney . When such chimneys are erected on the outside of a build- ing they shall be supported by a ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood