Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 20
Page 229
... combustible material nor less than eighteen inches ( 18 " ) from unprotected combustible material . Gas furnaces shall not be installed in any location inaccessible for inspection and re- pair . An opening or door not less than thirty ...
... combustible material nor less than eighteen inches ( 18 " ) from unprotected combustible material . Gas furnaces shall not be installed in any location inaccessible for inspection and re- pair . An opening or door not less than thirty ...
Page 230
... combustible partition . All such stoves shall be connected by a smoke pipe ... materials shall be at least three feet ( 3 ' ) above such installa- tions ... combustible material than six inches ( 6 " ) and if nearer than twelve inches ...
... combustible partition . All such stoves shall be connected by a smoke pipe ... materials shall be at least three feet ( 3 ' ) above such installa- tions ... combustible material than six inches ( 6 " ) and if nearer than twelve inches ...
Page 231
... combustible material above shall not be less than twelve inches ( 12 ′′ ) and if less than three feet ( 3 ' ) the ... materials by four inches ( 4 " ) of concrete , gypsum or terra cotta tile or an eight inch ( 8 " ) air space and a metal ...
... combustible material above shall not be less than twelve inches ( 12 ′′ ) and if less than three feet ( 3 ' ) the ... materials by four inches ( 4 " ) of concrete , gypsum or terra cotta tile or an eight inch ( 8 " ) air space and a metal ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood