... concrete shall conform to the A.S.T.M. " Tentative Specifications for Ready Mixed Concrete , " ( 94-42T ) . Admixtures of lime or finely pulverized inert materials may be added but not in excess of six per cent by volume of the cement ...
... concrete shall conform to the A.S.T.M. " Tentative Specifications for Ready Mixed Concrete , " ( 94-42T ) . Admixtures of lime or finely pulverized inert materials may be added but not in excess of six per cent by volume of the cement ...
Page 149
... concrete is deposited , unless Placing otherwise directed by the Building Inspector . Any flow of Concrete water into an excavation shall be diverted through proper side ( Cont'd . ) drains to a sump , or be removed by other approved ...
... concrete is deposited , unless Placing otherwise directed by the Building Inspector . Any flow of Concrete water into an excavation shall be diverted through proper side ( Cont'd . ) drains to a sump , or be removed by other approved ...
Page 250
... concrete 2 2 12 1 Grade B concrete Gunite 13 212 2 12 2 12 1 Steel or Cast Iron Col - Brick of clay , shale , con- crete or sand - lim.e umns ; Projecting Steel Beam or Girder Clay tile , clay tile and Flanges ; All Members concrete or ...
... concrete 2 2 12 1 Grade B concrete Gunite 13 212 2 12 2 12 1 Steel or Cast Iron Col - Brick of clay , shale , con- crete or sand - lim.e umns ; Projecting Steel Beam or Girder Clay tile , clay tile and Flanges ; All Members concrete or ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood